Item NO.:
|
IHDC 1-3KW |
Power : |
1000W / 2000W / 3000W
|
Certificate :
|
FCC CE ROHS
|
Lead Time : |
3-5 Work Day
|
Payment :
|
L/C T/T |
Warranty : | 1 Year |
MODEL | 1kw | 1.5kw | 2kw | 3kw | 4kw | 5KW | 6KW | |||||||
Continuous Output Power (W) | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | |||||||
Rated input voltage | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 24VDC/48VDC | |||||||||||
Mains mode specifications: | ||||||||||||||
Input voltage waveform | Sine wave (mains or generator) | |||||||||||||
Rated input voltage | 100V/110V/120V/220V/230V/240Vac | |||||||||||||
Low voltage shutdown point | 92/184Vac±4% | |||||||||||||
Low pressure recovery point | 97/194Vac ±4% | |||||||||||||
High voltage shutdown point | 127/253Vac±4% | |||||||||||||
High pressure recovery point | 121/243Vac±4% | |||||||||||||
Maximum AC input voltage | 135/270V rms | |||||||||||||
Rated input frequency | 50Hz/ 60Hz (automatic detection) | |||||||||||||
Low voltage recovery point frequency | 40.5+0.3Hz ; | |||||||||||||
Low voltage cut-off point frequency | 40+0.3Hz; | |||||||||||||
High voltage recovery point frequency | 69.5+0.3Hz; | |||||||||||||
High voltage cut-off point frequency | 70+0.3Hz ; | |||||||||||||
Output voltage waveform | Consistent with the input voltage waveform | |||||||||||||
Overload protection | Circuit breaker start | |||||||||||||
Short circuit protection | Circuit breaker start | |||||||||||||
Power Efficiency | >95% | |||||||||||||
Conversion current | 30A | |||||||||||||
Conversion time (Ac to Dc) | 10ms | |||||||||||||
Bypass switching current | Yes | |||||||||||||
Bypass maximum load current | 30A | |||||||||||||
Output voltage waveform | Sine wave | |||||||||||||
Power factor | 0~1.0 | |||||||||||||
Rated output voltage (V) | 120/230Vac | |||||||||||||
Rated output frequency (Hz) | 60/50Hz ± 0.3Hz | |||||||||||||
Automatic tracking main frequency (Hz) | Yes (from the first connection) | |||||||||||||
Output voltage range | ±2% rms | |||||||||||||
efficient | >80% | |||||||||||||
Overload protection (SMPS load) | (110%<load<125%) ±10%: disconnect the output voltage after 15 minutes | |||||||||||||
(125%<load <150%) ±10%: disconnect the output voltage after 10 seconds | ||||||||||||||
Load >150% ±10%: Disconnect the output voltage after 20 seconds | ||||||||||||||
Peak capacity(10s) | 3000VA | 4500VA | 6000VA | 9000VA | 1200VA | 15000VA | 18000VA | |||||||
start the motor | 1HP | 1.5HP | 2HP | 3HP | 4HP | 5HP | 6HP | |||||||
Short circuit protection | Current limit (power off after 10s) | |||||||||||||
Circuit breaker size | 15A | 20A | 30A | 40A | ||||||||||
Rated DC input voltage | 12V / 24V/48V | |||||||||||||
Minimum DC terminal voltage | 10V/20V/40V | |||||||||||||
Undervoltage warning | 10.5Vdc ± 0.3Vdc (12V power supply) | |||||||||||||
DC input voltage is too low, automatic power off | 10.0Vdc ± 0.3Vdc(12V power supply) | |||||||||||||
Input overvoltagewarning and power failure | 16Vdc ± 0.3Vdc (12Vpower supply) | |||||||||||||
Input overvoltage recovery | 15.5Vdc ± 0.3Vdc(12V power supply) | |||||||||||||
Power saving | load ≦2W | |||||||||||||
Inverter dimensions | 360*185*180mm | 420*185*180mm | 597*195*190mm | |||||||||||
(Length*width*height) | ||||||||||||||
Packing size (length*width*height) | 520*315*305 | 580*315*305mm | 760*325*310mm | |||||||||||
Inverter weight | 13.5KG | 14KG | 17KG | 21KG | 27KG | 29.5KG | 30.5KG | |||||||
Packing operating weight | 15.5KG | 15.5KG | 19KG | 23.5KG | 29.5KG | 31.5KG | 32.5KG | |||||||
Standard warranty | 2 year |